Nitrogen
NITROGEN REFRIGERATED LIQUID, NF Label
Nitrogen, Refrigerated Liquid, NF
UN1977 Rx ONLY
NON-FLAMMABLE GAS 2 ATG-08
AIRTEC GASES
LAS VEGAS, NV 89109
(702) 454-2400
Rx ONLY. WARNING: Administration of Nitrogen may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of Nitrogen and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications, and side effects, and the precautions to be taken.
WARNING: CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INUURY. MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION. Do not handle until all safety precautions have been read and understood. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. Use a back flow preventive device in the piping. DO NOT change or force fit connections. Close valve after each use and when empty. Always keep container in upright position. Read and follow the Safety Data Sheet (SDS) before use.
FIRST AID: IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention.
CAS: 7727-37-9 DO NOT REMOVE THIS PRODUCT LABEL.
Nitrogen Contents
General Requirements
Table of Liquid Contents
Number | Title | Revision Number |
N2 100 a6 | Liquid Nitrogen - Cylinder Weight-Volume Chart | 1.0 |
Liquid cylinders with gross water capacity of 176 & 196 liquid liters will contain the amount of nitrogen listed in the table below: |
NOTE: Cylinders with different water capacities must be filled to contain the amount of nitrogen in accordance with manufacturer’s recommendations. |
UNIT OF MEASURE | CONTENTS | NOTES |
Pounds | 267 | Maximum contents per manufacturers recommendation (MVE Cryogenics) |
298 | Maximum contents per manufacturers recommendation (MVE Cryogenics) for cylinders equipped with a relief valve set under 25 psig | |
SCF | 3230 | Maximum contents per manufacturers recommendation (MVE Cryogenics) Standard cubic feet of gas measured at 1 atmosphere and 70 degrees F using a conversion factor of 12.1 cu. ft. per pound |
3590 | Maximum contents per manufacturers recommendation (MVE Cryogenics) for cylinders equipped with a relief valve set under 25 psigStandard cubic feet of gas measured at 1 atmosphere and 70 degrees F using a conversion factor of 12.1 cu. ft. per pound | |
Liters | 89500 | Maximum contents per manufacturers recommendation (MVE Cryogenics) Liters of gas measured at 1 atmosphere and 70 degrees F using a conversion factor of 755.4 liters per kilogram and 0.4535 kilograms per pound |
99600 | Maximum contents per manufacturers recommendation (MVE Cryogenics) for cylinders equipped with a relief valve set under 25 psig Liters of gas measured at 1 atmosphere and 70 degrees F using a conversion factor of 755.4 liters per kilogram and 0.4535 kilograms per pound | |
Liquid Liters(Water Cap) | 160(176) | Maximum contents per manufacturers recommendation (MVE Cryogenics) |