OXYGEN COMPRESSED LABEL


OXYGEN COMPRESSED LABEL

OXYGEN COMPRESSED USP  UN 1072

PRODUCED BY AIR LIQUEFACTION

WARNING: HIGH PRESSURE OXIDIZING GAS VIGOROUSLY ACCELERATES COMBUSTION.  KEEP OIL AND GREASE AWAY.  OPEN VALVE SLOWLY.  STORE AND USE WITH ADEQUATE VENTILATION.  USE ONLY WITH EQUIPMENT CLEANED FOR OXYGEN SERVICE AND RATED FOR CYLINDER PRESSURE.  USE ONLY WITH PRESSURE REDUCING EQUIPMENT AND APPARATUS DESIGNED FOR OXYGEN SERVICE.  USE A BACK FLOW PREVENTATIVE IN THE PIPING.   CLOSE VALVE AFTER EACH USE AND WHEN EMPTY.  CYLINDER TEMPERATURES SHOULD NOT EXCEED 52 C (125 F)  USE IN ACCORDANCE WITH MATERIAL SAFETY DATA SHEET (MSDS)

.


GENERAL WARNINGS AND PRECAUTIONS

Warning: for emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation.  For all other medical applications Rx Only.  Uninterrupted use of high concentrations of oxygen over a long duration without monitoring oxygen content of arterial blood may be harmful.  Uninterrupted use of high concentrations of oxygen for more than 5 hours may be harmful.  Do not attempt to use on patients who have stopped breathing, unless used in conjunction with resuscitative equipment.

DO NOT REMOVE THIS PRODUCT LABEL


OXYGEN REFRIGERATED LIQUID LABEL

OXYGEN REFRIGERATED LIQUID U.S.P.  UN 1073ALWAYS KEEP CONTAINER IN UPRIGHT POSITIONWARNING: EXTREMELY COLD OXIDIZING LIQUID AND GAS UNDER PRESSURE.  VIGOROUSLY ACCELERATES COMBUSTION.  COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT.  CAN CAUSE SEVERE FROSTBITE.  STORE AND USE WITH ADEQUATE VENTILATION.  KEEP OIL, GREASE, AND COMBUSTIBLES AWAY.  NO SMOKING IN CONTAINER AREA.  DO NOT USE OR STORE NEAR HEAT OR OPEN FLAME.  USE ONLY WITH EQUIPMENT CLEANED FOR OXYGEN SERVICE.  DO NOT GET LIQUID IN EYES ON SKIN OR CLOTHING.  FOR LIQUID WITHDRAWAL, WEAR FACE SHIELD AND GLOVES.  DO NOT DROP  USE HAND TRUCK FOR CONTAINER MOVEMENT.  AVOID SPILLS.  DO NOT WALK ON OR ROLL EQUIPMENT OVER SPILLS.  CLOSE VALVE AFTER EACH USE AND WHEN EMPTY.  USE IN ACCORDANCE WITH MATERIAL SAFETY DATA SHEET (MSDS).FIRST AID:  IN CASE OF FROSTBITE OBTAIN MEDICAL TREATMENT IMMEDIATELY.


OXYGEN CERTIFICATE OF ANALYSIS

CUSTOMER ___________________  VENDOR / SUPPLIER ________________________  THIS LETTER IS TO PROVIDE YOU WITH THE                CERTIFICATION YOU REQUESTED FOR OXYGEN USP LOT NUMBER _______________________ SUPPLIED TO YOU IN               CYLINDERS / VESSELS BY OUR LOCATION                             These cylinders were filled in accordance with the Standard OperatingProcedures utilized for the manufacture of Medical Gases.  By               following these procedures, our location ensures that products aresafely manufactured in compliance with FDA’s Current Good ManufacturingPractices                (cGMP) Regulations.                CAUTION: VENDOR SUPPLIES THIS CERTIFICATION TO CUSTOMER TO ASSISTCUSTOMER IN ENSURING COMPLIANCE WITH 21 CFR 211.84.  THIS               CERTIFICATION DOES NOT ELIMINATE CUSTOMERS OBLIGATION TO COMPLY WITHOTHER PORTIONS OF 21 CFR 210 AND 211, INCLUDING BUT NOT              LIMITED TO 21 CFR 211.165 (FINISHED PRODUCT TESTING) FOR CYLINDERS ANDVESSELS FILLED FROM THESE SUPPLY CYLINDERS.  THESE CYLINDERS ARE               NOT CERTIFIED FOR INSTRUMENT CALIBRATION. TEST REQUIREMENT           USP SPECIFICATION                  LOT ANALYSISIDENTIFICATION                         PASS ODOR                                        PASS CARBON DIOXIDE                    LESS THAT 0.03% CARBON MONOXIDE                LESS THAT 0.001% ASSAY                                     GREATER THAN 99.0% * NOTE: The USP/NF exempts facilities that manufacture Oxygen USP by theAir Liquefaction process from the tests for Carbon Dioxide and CarbonMonoxide.                 As our label states, the Oxygen USP being supplied is manufactured by the Air Liquefaction Process. The methodology being used to perform the USP / NF Test for                Assay is indicated below:   Paramagnetic Analyzer    Model # _________________________               J 700 a1 REVISION 1.0               CERTIFICATE OF ANALYSIS - OXYGEN USP