These highlights do not include all the information needed to use MYDCOMBI® safely and effectively. See full prescribing information for MYDCOMBI. MYDCOMBI (tropicamide and phenylephrine hydrochloride ophthalmic spray) 1%/2.5%, for topical ophthalmic use Initial U.S. Approval: 2023


1 INDICATIONS AND USAGE

MYDCOMBI (tropicamide and phenylephrine hydrochloride ophthalmic spray) 1% / 2.5% is indicated to induce mydriasis for diagnostic procedures and in conditions where short term pupil dilation is desired.


2 DOSAGE AND ADMINISTRATION


2.1 Recommended Dosage

Administer one metered spray to the cornea of each eye to be dilated. Repeat after 5 minutes.


SPL UNCLASSIFIED SECTION

Pediatric Patients Younger Than 1 Year Old

In pediatric patients younger than 1 year old, administer one metered spray to the cornea of each eye to be dilated, up to a maximum of 3 sprays per eye per day.


2.2 Administration Instructions

The following steps should be followed sequentially:

  • Load the MYDCOMBI dispenser by depressing the FILL BUTTON at the top of the dispenser once.Figure 1: MYDCOMBI Dispenser Front (L) and Back (R) View
  • Hold MydCombi™ dispenser with thumb over Mist Button, wrapping other fingers around base.
  • Bring MydCombi™ dispenser to patient's eye with Mirror facing the eye.–The dispenser should be as close as patient's nose.–To prevent blinking, use your other hand to gently pull lower eyelid down or ask patient to pull her/his lid down.
  • Aim Mist Opening toward the center of eye.
  • Confirm Alignment Marks (on the Fill Button and the cartridge side) align with the center of eye.–Ask patient to confirm when their eye is centered on the BLUE Mirror.If patient is having trouble centering their eye on the blue light, ask that they look up, then look at the BLUE Mirror.
  • Firmly press and release Mist Button.–The drug solution should gently wet the eye. Repeat steps A to F if needed.
  • Administer a second metered spray after 5 minutes to each dilated eye.
  • Repeat steps A to G for the contralateral eye if it is to be dilated.

3 DOSAGE FORMS AND STRENGTHS

MYDCOMBI is a sterile, clear, colorless, topical ophthalmic spray containing tropicamide 1% (w/w) and phenylephrine hydrochloride 2.5% (w/w). Each metered spray delivers 0.008 mL which contains 0.08 mg tropicamide and 0.2 mg phenylephrine hydrochloride.


4 CONTRAINDICATIONS


4.1 Known Hypersensitivity

Contraindicated in persons showing known hypersensitivity to any component of the formulation.


5 WARNINGS AND PRECAUTIONS


5.1 Topical Ophthalmic Use

MYDCOMBI is not indicated for injection.


5.2 Blood Pressure Elevation

Caution should be exercised with the use of MYDCOMBI in pediatric patients less than 5 years of age and patients with hyperthyroidism, or cardiovascular disease. The post-treatment blood pressure of patients with cardiac and endocrine diseases and any patients who develop symptoms should be carefully monitored.


5.3 Central Nervous System Disturbances

Tropicamide in MYDCOMBI may cause CNS disturbances which may be dangerous in pediatric patients. The possibility of psychotic reactions and behavioral disturbances due to hypersensitivity to anticholinergic drugs should be considered.


5.4 Intraocular Pressure

Mydriatics may produce a transient elevation of intraocular pressure.


5.5 Rebound Miosis

Rebound miosis has been reported one day after receiving phenylephrine hydrochloride ophthalmic solution, and re-administration of the drug produced a lesser mydriatic effect.


6 ADVERSE REACTIONS

Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The most common adverse reactions (incidence < 2%) were transient blurred vision, reduced visual acuity, photophobia, and mild eye discomfort.


6.1 Ocular Adverse Reactions

Transient blurred vision, reduced visual acuity, photophobia, superficial punctate keratitis, and mild eye discomfort may occur. Increased intraocular pressure has been reported following the use of mydriatics.


6.2 Systemic Adverse Reactions

Dryness of the mouth, tachycardia, headache, allergic reactions, nausea, vomiting, pallor, central nervous system disturbances and muscle rigidity have been reported with the use of tropicamide. Psychotic reactions, behavioral disturbances, and vasomotor or cardiorespiratory collapse in children have been reported with the use of anticholinergic drugs.

A marked increase in blood pressure has been reported with the use of phenylephrine, particularly, but not limited to, low weight premature neonates, infants, and hypertensive patients.


7 DRUG INTERACTIONS


7.1 Agents That May Exaggerate Pressor Responses

Phenylephrine in MYDCOMBI may enhance the pressor effects of atropine-like drugs and induce tachycardia in some patients.


7.2 Cholinergic Agonists and Ophthalmic Cholinesterase Inhibitors

Tropicamide in MYDCOMBI may interfere with the antihypertensive action of carbachol, pilocarpine, or ophthalmic cholinesterase inhibitors.


7.3 Potent Inhalation Anesthetic Agents

Phenylephrine in MYDCOMBI may potentiate the cardiovascular depressant effects of some inhalation anesthetic agents.


8 USE IN SPECIFIC POPULATIONS


8.1 Pregnancy


SPL UNCLASSIFIED SECTION

Risk Summary

There are no available data on MYDCOMBI use in pregnant women or animals to inform any drug-associated risks. It is also not known whether tropicamide or phenylephrine can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. MYDCOMBI should be given to a pregnant woman only if clearly needed.


8.2 Lactation


SPL UNCLASSIFIED SECTION

Risk Summary

There are no data on the presence of tropicamide or phenylephrine in human milk from the administration of MYDCOMBI, the effects on the breastfed infant, or the effects on milk production. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for MYDCOMBI and any potential adverse effects on the breastfed child from MYDCOMBI.


8.4 Pediatric Use

Tropicamide in MYDCOMBI may rarely cause CNS disturbances which may be dangerous in pediatric patients. Psychotic reactions, behavioral disturbances, and vasomotor or cardiorespiratory collapse in children have been reported with the use of anticholinergic drugs [see Warnings and Precautions (5.3)].


8.5 Geriatric Use

No overall differences in safety or effectiveness of MYDCOMBI have been observed between patients 65 years of age and older and younger adult patients.


10 OVERDOSAGE

Overdosage of MYDCOMBI may cause a rapid rise in blood pressure. It may also cause headache, anxiety, nausea and vomiting, and ventricular arrhythmias. Prompt injection of a rapidly acting alpha- adrenergic blocking agent such as phentolamine has been recommended.


11 DESCRIPTION

MYDCOMBI is a sterile, clear, colorless fixed dose combination of an anticholinergic (tropicamide) and an alpha-adrenergic receptor agonist (phenylephrine hydrochloride) for topical ophthalmic use. The 2 active ingredients are represented by the chemical structures below.

Tropicamide:

Chemical Name: Benzeneacetamide, N-ethyl-α-(hydroxymethyl)-N-(4-pyridinylmethyl)-

Molecular Formula: C17H20N2O2

Molecular Weight: 284.35 g/mol

Phenylephrine Hydrochloride:

Chemical Name: (R)-3-hydroxy-α[(methylamino)methyl]benzenemethanol hydrochloride

Molecular Formula: C9H13NO2∙HCl

Molecular Weight: 203.67 g/mol

Each mL of MYDCOMBI ophthalmic spray (sterile) contains: ACTIVES: Phenylephrine Hydrochloride 2.5% (25 mg) equivalent to 20.6 mg of phenylephrine base, Tropicamide 1% (10 mg); INACTIVE: Hydrochloric Acid and/or Sodium Hydroxide may be added to adjust pH (pH 4.8–5.2), Water for Injection; PRESERVATIVE: Benzalkonium Chloride 0.01% (0.1 mg).


12 CLINICAL PHARMACOLOGY


12.1 Mechanism of Action

Tropicamide, the anticholinergic component of MYDCOMBI, blocks the responses of the sphincter muscle of the iris, dilating the pupil (mydriasis). Phenylephrine hydrochloride, the alpha-1 adrenergic agonist component of MYDCOMBI, acts as a mydriatic agent by contracting the dilator muscle of the iris.


12.2 Pharmacodynamics

MYDCOMBI acts in 15 to 30 minutes with maximal mydriasis occurring in 20 to 90 minutes. Darker irides tend to dilate slower than lightly pigmented irides and to achieve maximal effect may require more doses than lighter irides.

Mydriasis will reverse spontaneously with time, with recovery after 3 to 8 hours. Complete recovery from mydriasis in some individuals may require 24 hours.


13 CLINICAL STUDIES

Two Phase 3 clinical trials were conducted to evaluate the efficacy of MYDCOMBI for achievement of mydriasis. The MIST-1 study was a prospective, double-masked, active-controlled, 3-period cross-over, superiority study to compare the pupil dilating effect of MYDCOMBI to tropicamide 1% and to phenylephrine 2.5%, with all solutions topically administered by the Optejet® Dispenser (N = 64 subjects; 128 eyes). The MIST-2 study was a prospective, multicenter, double-masked, placebo-controlled, 3-period crossover, superiority study to compare the pupil dilating effect of MYDCOMBI to placebo (eyewash solution), with both solutions topically administered by the Optejet Dispenser (N = 70 subjects; 140 eyes).

The primary efficacy endpoint for both studies was the mean change in 35-minute pupil diameter compared to baseline as measured by digital pupillometry in highly photopic conditions. Data from the 2 studies are presented in Table 1. At 35 minutes post-dose, the mean change in pupil diameter was 4.7 mm with MYDCOMBI, 4.1 mm with tropicamide, and 0.9 mm with phenylephrine in MIST-1, and was 4.8 mm with MYDCOMBI and 0.1 mm with placebo in MIST-2. MYDCOMBI was statistically superior to tropicamide administered alone and phenylephrine administered alone.

MYDCOMBI provided a clinically significant effect in the proportion of eyes achieving pupil diameter of ≥ 6 mm at 35-minute post-dose in 94% of eyes compared to 78% of eyes administered tropicamide alone and 1.6% of eyes administered phenylephrine alone, and 0% of eyes administered placebo. As shown in Figure 2, peak effect was measured at the 80-minute evaluation when the mean change from baseline was 5.2 mm. Treatment differences in mydriasis were observed as early as 20 minutes and still present at 180 minutes post-dose, the end of the protocol-specified observation period.

Figure 2: MIST-1 and MIST-2 pooled, mean pupil diameter vs measurement time, by treatment group. Vertical bars show 95% confidence interval for the mean at each point. Smooth curves are based on an 8 degrees of freedom (df) generalized additive model (GAM) smooth through time, adjusting for baseline pupil diameter. Confidence intervals are not adjusted for correlation.

Mean Baseline (SD)2.6 (0.05)2.6 (0.05)2.6 (0.05)2.6 (0.04)2.6 (0.04)

14 HOW SUPPLIED/STORAGE AND HANDLING

MYDCOMBI is supplied as sterile, clear, colorless solution in a 2 mL vial enclosed in a dispenser cartridge. Each MYDCOMBI cartridge holds approximately 180 sprays.

Do not tamper with or attempt to open the MYDCOMBI cartridge. Such action may damage the dispenser causing an incorrect medication discharge volume; additionally, the dispenser base may not function properly.

Only use the MYDCOMBI cartridge with the MYDCOMBI Dispenser base which may be supplied separately. The MYDCOMBI base will not work with any other cartridges.

NDC 81046-0111-1. Carton containing one replacement sterile drug cartridge

NDC 81046-0111-2. Box containing one carton with one sterile drug cartridge, and one carton with one base unit

NDC 81046-0111-5. Box containing five cartons, each with one replacement sterile drug cartridge

The MYDCOMBI cartridge must be used prior to the expiration date on the cartridge.


STORAGE AND HANDLING SECTION

Storage: Store at room temperature 15°C to 25°C (59°F to 77°F).


SPL UNCLASSIFIED SECTION

Manufactured for Eyenovia, Inc. by Alcami Corporation


15 PATIENT COUNSELING INFORMATION

Advise patients that they may experience sensitivity to light and blurred vision while their pupils are dilated.

Advise patients not to drive, use machinery, or do any activity that requires clear vision until they are sure they can perform such activities safely.


INSTRUCTIONS FOR USE

MydCombi™(Tropicamide and Phenylephrine HCl Ophthalmic Spray), 1%/2.5%

Rx Only

INSTRUCTIONS FOR USEMydCombi™ Ophthalmic Spray

This "Instructions for Use" document has information about the administration of MydCombi™ (Tropicamide and Phenylephrine HCI Ophthalmic Spray) 1%/2.5%.

MydCombi™ is packaged in a dispenser that mists drug solution onto the eye. It has 2 parts – the cartridge that holds the drug solution, and the base that holds electronics.

Getting to know MydCombi™

How the MydCombi™ Dispenser Works

Understanding the Mist and Battery Lights

The Mist Light and the Battery Light show the status of the MydCombi™ dispenser.

Important Reminders and Cleaning Instructions

Storing the MydCombi™ Base and Cartridges

Store MydCombi™ bases and cartridges at room temperature 15°C to 25°C (59°F to 77°F). Protect from light and excessive heat.

The MydCombi™ base contains a lithium-ion battery. Damage to the base can cause fire. Do not puncture base or expose to excessive heat (≥ 50°C).

Li-Ion batteries may pose environmental and safety hazards and should be disposed of in accordance with all applicable Federal and State Laws. Check with all governing travel bodies for current requirements before air travel.

Assembling the MydCombi™ Dispenser

Complete these steps to assemble the MydCombi™ base and cartridge.

Note: If packaging is opened or damaged, do not use the contents. Instead, open a new base or cartridge, and contact your distributer for a replacement.

Preparing MydCombi™ for Use Each Day

Administering MydCombi™

Troubleshooting Tips

To report suspected adverse reactions please contact Eyenovia, Inc at 1-833-393-6684 (Option 1) or FDA at 1-800-FDA-1088 or http://www.fda.gov/medwatch.

Replacing the MydCombi™ Cartridge

Manufactured By:Eyenovia295 Madison Ave., Suite 2400New York, NY 10017

© 2022 Eyenovia, Inc. All rights reserved.

Getting to know MydCombi™3
How the MydCombi™ Dispenser Works3
Understanding the Mist and Battery Lights4
Important Reminders and Cleaning Instructions4
Storing the MydCombi™ Base and Cartridges5
Assembling the MydCombi™ Dispenser6
Preparing MydCombi™ for Use Each Day8
Administering MydCombi™9
Troubleshooting Tips10
Replacing the MydCombi™ Cartridge10
Symbols Used in Labels on the MydCombi™ Cartridge, Base and Packaging11
MydCombi™ Dispenser PartsMydCombi™ Assembled
Mist Light SOLID BLUEReady to dose
Mist Light BLINKING BLUE with Battery Light BLINKING RED & BLUEReset the dispenser-See "TROUBLESHOOTING TIPS" (page 10) for dispenser reset instructions. If lights continue blinking after dispenser reset, reset again. If lights continue to blink after second reset, change the cartridge.
Battery Light BLINKING GREENBattery is charging
Battery Light SOLID GREENBattery is fully charged
Battery Light BLINKING REDBattery is low
Battery Light SOLID REDCharge dispenser base at once
1.Assemblea.Remove base and/or cartridge from packaging.b.Align base and cartridge, then press together until they click.-Take care to avoid pressing Fill Button when assembling.
2.ChargeCharge MydCombi™ base before first use (see "MydCombi Base Charging and Electrical Information" contained with MydCombi™ base packaging). Charging may be performed either before or after assembly.a.Push micro-USB cable into Charging Port.b.Connect opposite end of USB cable to wall outlet plug or USB port.-Battery light BLINKS GREEN while charging.c.Charge until battery light turns SOLID GREEN, then disconnect cable from Charging Port.Note: Excessive charging may damage battery or decrease battery life. Charging weekly, or when the Battery Light begins blinking red (signaling low battery) is recommended.
3.Primea.Hold MydCombi™ dispenser upright.b.Firmly press Fill Button down until it stops, and Mist Light turns Blue.c.Slowly release Fill Button, while counting to 3.-If Fill Button does not return to position, press again until it is all the way down.-If Fill Button still does not return to position, get a new cartridge, and re-assemble (Steps 1 - 2 [page 6]).
 d.Point Mist Opening away from face.e.Firmly press, then release Mist Button.f.Repeat Steps a – e until mist emerges from opening.-If mist does not come out after repeating these steps 5 times, get a new cartridge and re-assemble (Steps 1 - 2 [page 6]). 4.MydCombi™ is now ready to use.
Important: A test mist must be performed each day before dosing is commenced.
1.Load drug solutiona.Hold MydCombi™ dispenser upright.b.Firmly press Fill Button down until it stops, and Mist Light turns Blue.c.Slowly release Fill Button, while counting to 3.-If Fill Button does not return to position, press again until it is all the way down.-If Fill Button still does not return to position, get a new cartridge, and re-assemble (Steps 1 - 2 [page 6]).
2.Do a test mista.Holding MydCombi™ dispenser upright, point Mist Opening away from face.b.Firmly press and release Mist Button.3.MydCombi™ is ready to use.
Important: Keep MydCombi™ dispenser upright during use to maintain dose volume.
1.Load drug solutiona.Hold MydCombi™ dispenser upright and firmly press Fill Button down until it stops, and Mist Light turns Blue.b.Slowly release Fill Button, while counting to 3.
2.Align MydCombi™ with patient's eyea.Hold MydCombi™ dispenser with thumb over Mist Button, wrapping other fingers around base. b.Bring MydCombi™ dispenser to patient's eye with Mirror facing the eye.-The dispenser should be as close as patient's nose.-To prevent blinking, use your other hand to gently pull lower eyelid down or ask patient to pull her/his lid down.c.Aim Mist Opening toward the center of eye.d.Confirm Alignment Marks (on the Fill Button and the cartridge side) align with the center of eye.-Ask patient to confirm when their eye is centered on the BLUE Mirror.If patient is having trouble centering their eye on the blue light, ask that they look up, then look at the BLUE Mirror.
3.Press Mist Buttona.Firmly press and release Mist Button.-The drug solution should gently wet the eye. Repeat Steps 1-3 if needed.
1.Remove cartridgea.Hold MydCombi™ base in one hand. With other hand, press and squeeze Release Tabs on each side of cartridge.b.Pull cartridge and base apart.c.Place used cartridge in original tray and box for disposal or recycling.
Symbols Used in Labels on the MydCombi™ Cartridge, Base and Packaging
CAUTION, CONSULT ACCOMPANYING DOCUMENTSUSE BY (YYYY-MM: YEAR-MONTH)
SEE INSTRUCTIONS FOR USESTERILIZED USING ETHYLENE OXIDE
CATALOG NUMBERNON-STERILE
BATCH CODEDO NOT RESTERILIZE
QUANTITYLITHIUM-ION BATTERY - TO BE APPROPRIATELY RECYCLED
DATE OF MANUFACTURE (YYYY-MM : YEAR-MONTH)KEEP DRY
MANUFACTURERGHS LITHIUM-ION DISPOSAL
DO NOT USE IF THE PACKAGING HAS BEEN OPENED OR DAMAGEDELECTRONIC EQUIPMENT. DO NOT THROW IN TRASH.
WARNING: ELECTRICITYBY PRESCRIPTION ONLY
PROTECTED AGAINST VERTICALLY FALLING WATER DROPS UP TO 15-DEGREE ANGLETYPE BF PART COMPLYING WITH IEC 60601-1
  • The MydCombi™ Cartridge holds the drug solution.
  • The MydCombi™ Base supplies power to the dispenser.
  • The Fill Button is pressed to load the drug solution for topical ophthalmic administration.
  • The Mist Opening is where drug solution comes out when the Mist Button is pressed.
  • The Light and Mirror around the Mist Opening and the Eye Alignment Marks on the top and each side of the cartridge help align the eye for drug administration.
  • The Battery Light shows how much electrical charge remains in the Base.
  • The Release Tabs on each side of the cartridge are used to separate the cartridge and base when replacing cartridges.
  • The MydCombi™ Base is charged using a Micro-USB to USB Cable with Wall Plug or USB port (supplied separately). See "MydCombi™ Base Charging and Electrical Information" .

Mydcombi™ Base Charging and Electrical Information

1. Charging the Mydcombi™ Base

NOTE: Do not use base if packaging is opened or damaged. Get a new package by contacting your Eyenovia sales representative or calling 1-833-393-6684 (choose Option 1).

2. Specifications for Mydcombi Base and Charger

3. EMC

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in professional medical equipment. This equipment generates, uses, and radiates radio frequency energy and, if not prepared and used in accordance with instructions, may cause harmful interference to radio communications. There is no guarantee, however, that interference will not occur in a particular setting. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off/on, the user is encouraged to try to correct the interference by one or more of the following measures:

Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the device.

Guidance and Manufacturer's Declaration

This device is intended for use in the electromagnetic environment specified below. The device user should assure use in such an environment.

4. Disposal

5. Notes on Safety

Warnings and Recommendations

6. Reporting to Manufacturer and Authorities

If a serious incident occurs in connection with this device that affects the user or another person, please report incident to Eyenovia by calling 1-833-393-6684 (choose Option 1) or FDA at 1-800-FDA-1088 or http://www.fda.gov/medwatch.

7. Symbols Used in Labels on Mydcombi™ Base and Packaging

1. Charging the Mydcombi™ Base3
2. Specifications for Mydcombi Base and Charger4
3. EMC5
4. Disposal7
5. Notes on Safety7
6. Reporting to Manufacturer and Authorities7
7. Symbols Used in Labels on Mydcombi™ Base and Packaging8
Type of Charger: Micro-USB to USB Cable with Wall Plug or USB port (see section 2 for specifications)
Charge Mydcombi™ Base Before First Use
Charging may be performed either before or after assembly with Mydcombi™ cartridge.Refer to "Instructions for Use - Mydcombi™ Ophthalmic Spray" for information on cartridge/base assembly and drug administration.Perform the following steps to charge base: Push micro-USB cable into charging port.Connect opposite end of USB cable to wall outlet plug or USB port.-Battery light BLINKS GREEN while charging.Charge until battery light turns SOLID GREEN, then disconnect cable from base.Note: Excessive charging may damage battery or decrease battery life. Charging weekly, or when the LED light begins blinking red (signaling low battery), is recommended.
Battery Indicators on Mydcombi™ Base
If Battery Light is…It means…
BLINKING GREENBattery is charging
SOLID GREENBattery is fully charged
BLINKING REDBattery is low
SOLID REDCharge base at once
Operating power4.1VDC
Power sourceInternally powered, Lithium-Ion Battery
Instrument make / modelEyenovia / Mydcombi™ Base
Dimensions50 length, 120mm height, 40mm width (When assembled with cartridge)
Weight (system)< 100g (When assembled with cartridge)
Allowed operating temperature range15°C to 25°C (59°F to 77°F)
Allowed shipping and storage temperature range15°C to 25°C (59°F to 77°F) at relative humidity of 15% to 90% RH, non-condensing
Allowed operation, storage, and shipping humidity range15°C to 25°C (59°F to 77°F) at relative humidity of 15% to 90% RH, non-condensing
Allowed operation, storage, and shipping atmospheric pressure700hPa to 1060hPa
Electrical shock protection - Classification / DegreeInternally powered Class I
Battery life2-4 weeks, if used as indicated.
Use LifeDo not use base longer than 12 months from date of first use, or after Use By Date
Software versionSoftware version number can be obtained by calling the manufacturer.
TypeSwitching Power Supply
Input100-240V~, 50/60 Hz 200mA
Output5V, 1A
USB Cable Minimum Requirements5V, 1A
USB cable must be UL Listed. Must meet US Standard Level VI energy efficiency. Must meet DOE & CEC regulatory requirements.Examples of acceptable cables include those with UL number E178074 or Homespot Model S005AYU0500100.
Electromagnetic emissions
Emissions TestCompliance
RF emissions CISPR 11Group 1
RF emissions CISPR 11Class B
Harmonic Emissions IEC 61000-3-2Class B
Voltage Fluctuations/Flicker emissions IEC 61000-3-3Complies
Electromagnetic immunity
Phenomena of a continuous natureShall operate as intended.Shall be no degradation of performance.Shall be no loss of function.
Phenomena of transient natureFunctions shall be self-recoverable.Shall operate as intended after recovering.Shall be no degradation of performance,
Power interruption exceeding a certain timeFunctions shall be recoverable by the operator.Shall operate as intended after recovering.Shall be no degradation of performance.
Immunity TestIEC 60601 Test LevelCompliance Level
Electrostatic fast transient/burst IEC 61000-4-4 (Charging Only)±2 kV for power supply lines±2 kV for power supply lines
Surge IEC 61000-4-5 EN/IEC 61000-4-3 L-N (Charging Only)±1 kV differential mode±1 kV differential mode
EN/IEC 61000-4-3 (Charging Only)Radiated Immunity3 V/m, 80 – 2700 MHz80% AM at 1 kHz & Proximity Fields from RFWireless Communications EquipmentRadiated Immunity3 V/m, 80 – 2700 MHz80% AM at 1 kHz & Proximity Fields from RFWireless Communications Equipment
Voltage dips, short interruptions, and voltage variations on power supply input lines IEC 61000-4-11Voltage Dips 30% reduction, 25/30 periodsAt 0°Voltage Dips 30% reduction, 25/30 periodsAt 0°
Voltage Dips > 95% reduction, 0.5 periodAt 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315° Voltage Dips > 95% reduction, 0.5 periodAt 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°
Voltage Dips > 95 reduction, 1 periodAt 0°Voltage Dips > 95 reduction, 1 periodAt 0°
Voltage Interruptions > 95% reduction, 250/300 periodsVoltage Interruptions > 95% reduction, 250/300 periods
Conducted RF EN/IEC 61000-4-6Continuous Conducted RF,80% AM (1 kHz)3 Vrms, 0.15-80 MHz6 Vrms in ISM and amateur radio Bands within 150kHz – 80MHzContinuous Conducted RF,80% AM (1 kHz)3 Vrms, 0.15-80 MHz6 Vrms in ISM and amateur radio Bands within 150kHz – 80MHz
Magnetic field IEC 61000-4-8Power Frequency Magnetic Field 30Arms/m at 50/60HzPower Frequency Magnetic Field 30Arms/m at 50/60Hz
385380 –390TETRA 400Pulse 18 Hz1.80.327
450430 – 470GMRS 460, FRS 460FM As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because, while it does not represent actual modulation, it would be worst case. ± 5 kHz Deviation 1 kHz sine20.328
710704 – 787LTE Band 13, 17Pulse 217 Hz0.20.39
745
780
810800 – 960GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5Pulse 18 Hz20.328
870
930
17201 700 – 1 990GSM 1800; CDMA 1900; GSM 1900; DECT; LTE Band 1, 3, 4, 25; UMTSPulse 217 Hz20.328
1845
1970
24502 400 – 2 570Bluetooth, WLAN, 802.11 b/g/n, RFID 2450, LTE Band 7Pulse 217 Hz20.328
52405 100 – 5 800WLAN 802.11 a/nPulse 217 Hz0.20.39
5500
5785
Recommended separation distances between portable and mobile RF communications equipment and the device, except for the distances indicated in the following table "Immunity to RF Wireless Communications Equipment".
The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Users can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter (W) Separation distance according to frequency of transmitter (m)
150 kHz to 80 MHz d = 1.2√P80 MHz to 800 MHz d = 1.2√P800 MHz to 2.7 GHz d = 2.3√P
0.010.120.120.23
0.10.380.380.73
11.21.22.3
103.83.87.3
100121223
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.
CAUTION, CONSULT ACCOMPANYING DOCUMENTSUSE BY (YYYY-MM: YEAR-MONTH)
SEE INSTRUCTIONS FOR USEELECTRONIC EQUIPMENT. DO NOT THROW IN TRASH.
CATALOG NUMBERNON-STERILE
BATCH CODEKEEP DRY
QUANTITYLITHIUM-ION BATTERY - TO BE APPROPRIATELY RECYCLED
DATE OF MANUFACTURE (YYYY-MM : YEAR-MONTH)MANUFACTURER
WARNING: ELECTRICITYCAUTION: FEDERAL LAW RESTRICTS THIS PRODUCT
PROTECTED AGAINST VERTICALLY FALLING WATER DROPS UP TO 15-DEGREE ANGLETYPE BF PART COMPLYING WITH IEC 60601-1
Eyenovia, Inc.8748 Technology Way, Reno, NV 89521© 2022 Eyenovia, Inc. All rights reserved.www.eyenovia.comContact your sales representative or Eyenovia for product returns. Call 1-833-EYENOVIA (393-6684)admin@eyenovia.com
  • Reorient or relocate the receiving antenna
  • Increase the separation between the device and receiver
  • Connect the device into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help